• Schneider ATV960C25T4X1 High Performance Drive System ATV960 - 280/220kW - 480 V - IP23

Schneider ATV960C25T4X1 High Performance Drive System ATV960 - 280/220kW - 480 V - IP23

Main
range of product
Altivar Process ATV900
product or component type
Variable speed drive
device application
Industrial application
device short name
ATV960
product destination
Asynchronous motors
Synchronous motors
assembly style
In floor-standing enclosure compact version
provided equipment
Graphical operating panel in the enclosure door
Frequency inverter
Main switch
Line choke
Terminal block for main supply
Terminal block for motor
Enclosure for Spacial SF
cable entry
Bottom
colour of enclosure
Light grey RAL 7035
IP degree of protection
IP23 conforming to IEC 61800-5-1
type of cooling
Forced convection
[Us] rated supply voltage
480 V (+/- 10 %)
supply frequency
50/60 Hz (+/- 5 %)
network number of phases
3 phases
overvoltage category
III
asynchronous motor control profile
Constant torque standard
Variable torque standard
Optimized torque mode
synchronous motor control profile
Permanent magnet motor
output voltage
<= power supply voltage
permissible temporary current boost
1.5 x In for 60 s (heavy duty)
1.2 x In for 60 s (normal duty)
nominal switching frequency
2.5 kHz
switching frequency
2...8 kHz adjustable with derating factor
speed drive output frequency
0.1...500 Hz
motor power kW
220 kW (heavy duty)
280 kW (normal duty)
continuous output current
477 A at 2.5 kHz (normal duty)
370 A at 2.5 kHz (heavy duty)
line current
400 A at 480 V (normal duty)
323 A at 480 V (heavy duty)
apparent power
333 kVA at 480 V (normal duty)
268 kVA at 480 V (heavy duty)
THDI
<= 48 % full load conforming to IEC 61000-3-12
short-circuit protection
Upstream : 500 A gG fuse (normal duty)
Upstream : 400 A gG fuse (heavy duty)
Internal : 315 A 2 aR fuse
power dissipation in W
5750 W total (normal duty)
4340 W total (heavy duty)
730 W control part (normal duty)
520 W control part (heavy duty)
volume of cooling air
140 m3/h for control
1160 m3/h for power
noise level
70 dB 86/188/EEC - physical agents (noise) directive
prospective line Isc
50 kA for 100 ms
electrical connection
Control : removable screw terminals 0.5...1.5 mm²
Main supply : M12 bar
Motor : M12 bar
motor recommanded cable cross section
2 x (3 x 150 mm²) (normal duty)
3 x (3 x 95 mm²) (normal duty)
2 x (3 x 120 mm²) (heavy duty)
3 x (3 x 70 mm²) (heavy duty)
width
600 mm
height
2150 mm
depth
664 mm
product weight
400 kg
number of preset speeds
16 preset speeds
communication port protocol
Ethernet/IP
Modbus serial
Modbus TCP
option module
Slot A : communication module for Profibus DP V1
Slot A : communication module for Profinet
Slot A : communication module for DeviceNet
Slot A : communication module for CANopen daisy chain RJ45
Slot A : communication module for CANopen SUB-D 9
Slot A : communication module for CANopen screw terminals
Slot A : communication module for EtherCAT
Slot A/slot B/slot C : digital and analog I/O extension module
Slot A/slot B/slot C : output relay extension module
Slot B : 5/12 V digital encoder interface module
Slot B : analog encoder interface module
Slot B : resolver encoder interface module
safety function
STO (safe torque off) SIL 3 for <= 100 ms
EMC filter
Integrated conforming to EN/IEC 61800-3 category C3 shielded cable with <= 50 m motor cable maxi
Integrated conforming to EN/IEC 61800-3 category C4 unshielded cable with <= 80 m motor cable maxi
Complementary
maximum transient current
555 A 60 s per 10 min heavy duty
572 A 60 s per 10 min normal duty
motor slip compensation
Adjustable
Automatic whatever the load
Can be suppressed
Not available in permanent magnet motor law
acceleration and deceleration ramps
Linear adjustable separately from 0.01 to 9000 s
S, U or customized
braking to standstill
By DC injection
protection type
Motor : thermal protection
Motor : safe torque off
Motor : motor phase break
Drive : thermal protection
Drive : safe torque off
Drive : overheating
Drive : short-circuit protection
Drive : motor phase break
Drive : line supply overvoltage
Drive : line supply undervoltage
Drive : line supply phase loss
Drive : overspeed
Drive : break on the control circuit
Drive : overcurrent (between output phases and earth)
Drive : overload (output)
Drive : overvoltage (DC bus)
Drive : short-circuit protection with semi-conductor fuse (main supply)
Drive : fan monitoring
frequency resolution
Display unit : 0.1 Hz
Analog input : 0.012/50 Hz
connector type
2 RJ45 (on the control block) for Ethernet IP/Modbus TCP
1 RJ45 (on the control block) for Modbus serial
physical interface
2-wire RS 485 for Modbus serial
transmission frame
RTU for Modbus serial
transmission rate
10/100 Mbit/s for Ethernet IP/Modbus TCP
4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
exchange mode
Half duplex, full duplex, autonegotiation for Ethernet IP/Modbus TCP
data format
8 bits, configurable odd, even or no parity for Modbus serial
type of polarization
No impedance for Modbus serial
number of addresses
1...247 for Modbus serial
method of access
Slave for Modbus TCP
supply
External supply for digital inputs : 24 V DC (19...30 V) current <= 1.25 mA (overload and short-circuit protection)
Internal supply for reference potentiometer (1 to 10 kOhm) : 10.5 V DC +/- 5 % current <= 10 mA (overload and short-circuit protection)
Internal supply for digital inputs and STO : 24 V DC (21...27 V) current <= 200 mA (overload and short-circuit protection)
local signalling
LCD display unit, located on front door for operation function, status and configuration
analogue input type
Software-configurable voltage AI1, AI2, AI3 : 0...10 V DC impedance 30 kOhm, resolution 12 bits
Software-configurable current AI1, AI2, AI3 : 0...20 mA impedance 250 Ohm, resolution 12 bits
discrete input number
10
discrete input type
Programmable DI1...DI8 : 24 V DC (<= 30 V) impedance 3.5 kOhm
Programmable as pulse input DI7, DI8 0...30 kHz : 24 V DC (<= 30 V)
Safe torque off STOA, STOB : 24 V DC (<= 30 V) impedance > 2.2 kOhm
input compatibility
Discrete input STOA, STOB : level 1 PLC conforming to EN/IEC 61131-2
Discrete input DI1...DI8 : level 1 PLC conforming to EN/IEC 61131-2
Pulse input DI7, DI8 : level 1 PLC conforming to IEC 65A-68
discrete input logic
STOA, STOB, positive logic (source) : < 5 V (state 0) > 11 V (state 1)
DI1...DI8, positive logic (source) : < 5 V (state 0) > 11 V (state 1)
DI1...DI8, negative logic (sink) : > 16 V (state 0) < 10 V (state 1)
DI7, DI8, positive logic (source) : < 0.6 V (state 0) > 2.5 V (state 1)
analogue output number
2
analogue output type
Software-configurable voltage AQ1, AQ2 : 0...10 V DC impedance 470 Ohm, resolution 10 bits
Software-configurable current AQ1, AQ2 : 0...20 mA impedance 500 Ohm, resolution 10 bits
discrete output number
2
discrete output type
Logic output DQ+ : 0...1 kHz (<= 30 V) DC, 100 mA
Logic output DQ- : 0...1 kHz (<= 30 V) DC, 100 mA
Programmable as pulse output DQ+ : 0...30 kHz (<= 30 V) DC, 100 mA
sampling duration
Discrete input DI1...DI8 : 2 ms (+/- 0.5 ms)
Pulse input DI7, DI8 : 5 ms (+/- 1 ms)
Analog input AI1, AI2, AI3 : 1 ms (+/- 1 ms)
Analog output AQ1, AQ2 : 5 ms (+/- 1 ms)
accuracy
Analog input AI1, AI2, AI3 : +/- 0.6 % for a temperature variation 60 °C
Analog output AQ1, AQ2 : +/- 1 % for a temperature variation 60 °C
linearity error
Analog input AI1, AI2, AI3 : +/- 0.15 % of maximum value
Analog output AQ1, AQ2 : +/- 0.2 %
relay output number
3
relay output type
Configurable relay logic R1 : fault relay NO/NC electrical durability 100000 cycles
Configurable relay logic R2 : sequence relay NO electrical durability 1000000 cycles
Configurable relay logic R3 : sequence relay NO electrical durability 1000000 cycles
refresh time
5 ms +/- 0.5 ms R1, R2, R3 relay output
minimum switching current
Relay output R1, R2, R3 : 5 mA at 24 V DC
maximum switching current
Relay output R1 on resistive load (cos phi = 1) : 3 mA at 250 V AC
Relay output R1 on resistive load (cos phi = 1) : 3 mA at 30 V DC
Relay output R1 on inductive load (cos phi = 0.4 and L/R = 7 ms) : 2 mA at 250 V AC
Relay output R1 on inductive load (cos phi = 0.4 and L/R = 7 ms) : 2 mA at 30 V DC
Relay output R2, R3 on resistive load (cos phi = 1) : 5 mA at 250 V AC
Relay output R2, R3 on resistive load (cos phi = 1) : 5 mA at 30 V DC
Relay output R2, R3 on inductive load (cos phi = 0.4 and L/R = 7 ms) : 2 mA at 250 V AC
Relay output R2, R3 on inductive load (cos phi = 0.4 and L/R = 7 ms) : 2 mA at 30 V DC
isolation
Between power and control terminals

Write a review

Note: HTML is not translated!
    Bad           Good
Captcha
ATV960C25T4X1

Schneider ATV960C25T4X1 High Performance Drive System ATV960 - 280/220kW - 480 V - IP23

Schneider
2024-10-29
  • Brand: Schneider
  • Product Code: ATV960C25T4X1
  • Availability: 10
  • $1,000.00

  • Ex Tax: $1,000.00

Tags: ATV960C25T4X1